cleaned unused examples - 3
This commit is contained in:
@@ -0,0 +1,656 @@
|
||||
/**************************************************************************************************
|
||||
Filename: battservice.c
|
||||
Revised: $Date $
|
||||
Revision: $Revision $
|
||||
|
||||
Description: This file contains the Battery service.
|
||||
|
||||
Copyright 2012-2013 Texas Instruments Incorporated. All rights reserved.
|
||||
|
||||
IMPORTANT: Your use of this Software is limited to those specific rights
|
||||
granted under the terms of a software license agreement between the user
|
||||
who downloaded the software, his/her employer (which must be your employer)
|
||||
and Texas Instruments Incorporated (the "License"). You may not use this
|
||||
Software unless you agree to abide by the terms of the License. The License
|
||||
limits your use, and you acknowledge, that the Software may not be modified,
|
||||
copied or distributed unless embedded on a Texas Instruments microcontroller
|
||||
or used solely and exclusively in conjunction with a Texas Instruments radio
|
||||
frequency transceiver, which is integrated into your product. Other than for
|
||||
the foregoing purpose, you may not use, reproduce, copy, prepare derivative
|
||||
works of, modify, distribute, perform, display or sell this Software and/or
|
||||
its documentation for any purpose.
|
||||
|
||||
YOU FURTHER ACKNOWLEDGE AND AGREE THAT THE SOFTWARE AND DOCUMENTATION ARE
|
||||
PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED,
|
||||
INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, TITLE,
|
||||
NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
|
||||
TEXAS INSTRUMENTS OR ITS LICENSORS BE LIABLE OR OBLIGATED UNDER CONTRACT,
|
||||
NEGLIGENCE, STRICT LIABILITY, CONTRIBUTION, BREACH OF WARRANTY, OR OTHER
|
||||
LEGAL EQUITABLE THEORY ANY DIRECT OR INDIRECT DAMAGES OR EXPENSES
|
||||
INCLUDING BUT NOT LIMITED TO ANY INCIDENTAL, SPECIAL, INDIRECT, PUNITIVE
|
||||
OR CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST DATA, COST OF PROCUREMENT
|
||||
OF SUBSTITUTE GOODS, TECHNOLOGY, SERVICES, OR ANY CLAIMS BY THIRD PARTIES
|
||||
(INCLUDING BUT NOT LIMITED TO ANY DEFENSE THEREOF), OR OTHER SIMILAR COSTS.
|
||||
|
||||
Should you have any questions regarding your right to use this Software,
|
||||
contact Texas Instruments Incorporated at www.TI.com.
|
||||
**************************************************************************************************/
|
||||
|
||||
/*********************************************************************
|
||||
* INCLUDES
|
||||
*/
|
||||
#include "bcomdef.h"
|
||||
#include "OSAL.h"
|
||||
#include "hal_adc.h"
|
||||
#include "linkdb.h"
|
||||
#include "att.h"
|
||||
#include "gatt.h"
|
||||
#include "gatt_uuid.h"
|
||||
#include "gattservapp.h"
|
||||
#include "hid_uuid.h"
|
||||
#include "hiddev.h"
|
||||
|
||||
#include "battservice.h"
|
||||
|
||||
/*********************************************************************
|
||||
* MACROS
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* CONSTANTS
|
||||
*/
|
||||
|
||||
// ADC voltage levels
|
||||
#define BATT_ADC_LEVEL_3V 409
|
||||
#define BATT_ADC_LEVEL_2V 273
|
||||
|
||||
#define BATT_LEVEL_VALUE_IDX 2 // Position of battery level in attribute array
|
||||
#define BATT_LEVEL_VALUE_CCCD_IDX 3 // Position of battery level CCCD in attribute array
|
||||
|
||||
/*********************************************************************
|
||||
* TYPEDEFS
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* GLOBAL VARIABLES
|
||||
*/
|
||||
// Battery service
|
||||
CONST uint8 battServUUID[ATT_BT_UUID_SIZE] =
|
||||
{
|
||||
LO_UINT16(BATT_SERVICE_UUID), HI_UINT16(BATT_SERVICE_UUID)
|
||||
};
|
||||
|
||||
// Battery level characteristic
|
||||
CONST uint8 battLevelUUID[ATT_BT_UUID_SIZE] =
|
||||
{
|
||||
LO_UINT16(BATT_LEVEL_UUID), HI_UINT16(BATT_LEVEL_UUID)
|
||||
};
|
||||
|
||||
/*********************************************************************
|
||||
* EXTERNAL VARIABLES
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* EXTERNAL FUNCTIONS
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* LOCAL VARIABLES
|
||||
*/
|
||||
|
||||
// Application callback
|
||||
static battServiceCB_t battServiceCB;
|
||||
|
||||
// Measurement setup callback
|
||||
static battServiceSetupCB_t battServiceSetupCB = NULL;
|
||||
|
||||
// Measurement teardown callback
|
||||
static battServiceTeardownCB_t battServiceTeardownCB = NULL;
|
||||
|
||||
// Measurement calculation callback
|
||||
static battServiceCalcCB_t battServiceCalcCB = NULL;
|
||||
|
||||
static uint16 battMinLevel = BATT_ADC_LEVEL_2V; // For VDD/3 measurements
|
||||
static uint16 battMaxLevel = BATT_ADC_LEVEL_3V; // For VDD/3 measurements
|
||||
|
||||
// Critical battery level setting
|
||||
static uint8 battCriticalLevel;
|
||||
|
||||
// ADC channel to be used for reading
|
||||
static uint8 battServiceAdcCh = HAL_ADC_CHANNEL_VDD;
|
||||
|
||||
/*********************************************************************
|
||||
* Profile Attributes - variables
|
||||
*/
|
||||
|
||||
// Battery Service attribute
|
||||
static CONST gattAttrType_t battService = { ATT_BT_UUID_SIZE, battServUUID };
|
||||
|
||||
// Battery level characteristic
|
||||
static uint8 battLevelProps = GATT_PROP_READ | GATT_PROP_NOTIFY;
|
||||
static uint8 battLevel = 100;
|
||||
static gattCharCfg_t battLevelClientCharCfg[GATT_MAX_NUM_CONN];
|
||||
|
||||
// HID Report Reference characteristic descriptor, battery level
|
||||
static uint8 hidReportRefBattLevel[HID_REPORT_REF_LEN] =
|
||||
{ HID_RPT_ID_BATT_LEVEL_IN, HID_REPORT_TYPE_INPUT };
|
||||
|
||||
/*********************************************************************
|
||||
* Profile Attributes - Table
|
||||
*/
|
||||
|
||||
static gattAttribute_t battAttrTbl[] =
|
||||
{
|
||||
// Battery Service
|
||||
{
|
||||
{ ATT_BT_UUID_SIZE, primaryServiceUUID }, /* type */
|
||||
GATT_PERMIT_READ, /* permissions */
|
||||
0, /* handle */
|
||||
(uint8 *)&battService /* pValue */
|
||||
},
|
||||
|
||||
// Battery Level Declaration
|
||||
{
|
||||
{ ATT_BT_UUID_SIZE, characterUUID },
|
||||
GATT_PERMIT_READ,
|
||||
0,
|
||||
&battLevelProps
|
||||
},
|
||||
|
||||
// Battery Level Value
|
||||
{
|
||||
{ ATT_BT_UUID_SIZE, battLevelUUID },
|
||||
GATT_PERMIT_READ,
|
||||
0,
|
||||
&battLevel
|
||||
},
|
||||
|
||||
// Battery Level Client Characteristic Configuration
|
||||
{
|
||||
{ ATT_BT_UUID_SIZE, clientCharCfgUUID },
|
||||
GATT_PERMIT_READ | GATT_PERMIT_WRITE,
|
||||
0,
|
||||
(uint8 *) &battLevelClientCharCfg
|
||||
},
|
||||
|
||||
// HID Report Reference characteristic descriptor, batter level input
|
||||
{
|
||||
{ ATT_BT_UUID_SIZE, reportRefUUID },
|
||||
GATT_PERMIT_READ,
|
||||
0,
|
||||
hidReportRefBattLevel
|
||||
}
|
||||
};
|
||||
|
||||
|
||||
/*********************************************************************
|
||||
* LOCAL FUNCTIONS
|
||||
*/
|
||||
static uint8 battReadAttrCB( uint16 connHandle, gattAttribute_t *pAttr,
|
||||
uint8 *pValue, uint8 *pLen, uint16 offset, uint8 maxLen );
|
||||
static bStatus_t battWriteAttrCB( uint16 connHandle, gattAttribute_t *pAttr,
|
||||
uint8 *pValue, uint8 len, uint16 offset );
|
||||
static void battNotifyCB( linkDBItem_t *pLinkItem );
|
||||
static uint8 battMeasure( void );
|
||||
static void battNotifyLevel( void );
|
||||
|
||||
/*********************************************************************
|
||||
* PROFILE CALLBACKS
|
||||
*/
|
||||
// Battery Service Callbacks
|
||||
CONST gattServiceCBs_t battCBs =
|
||||
{
|
||||
battReadAttrCB, // Read callback function pointer
|
||||
battWriteAttrCB, // Write callback function pointer
|
||||
NULL // Authorization callback function pointer
|
||||
};
|
||||
|
||||
/*********************************************************************
|
||||
* PUBLIC FUNCTIONS
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_AddService
|
||||
*
|
||||
* @brief Initializes the Battery Service by registering
|
||||
* GATT attributes with the GATT server.
|
||||
*
|
||||
* @return Success or Failure
|
||||
*/
|
||||
bStatus_t Batt_AddService( void )
|
||||
{
|
||||
uint8 status = SUCCESS;
|
||||
|
||||
// Initialize Client Characteristic Configuration attributes
|
||||
GATTServApp_InitCharCfg( INVALID_CONNHANDLE, battLevelClientCharCfg );
|
||||
|
||||
// Register GATT attribute list and CBs with GATT Server App
|
||||
status = GATTServApp_RegisterService( battAttrTbl,
|
||||
GATT_NUM_ATTRS( battAttrTbl ),
|
||||
&battCBs );
|
||||
|
||||
return ( status );
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_Register
|
||||
*
|
||||
* @brief Register a callback function with the Battery Service.
|
||||
*
|
||||
* @param pfnServiceCB - Callback function.
|
||||
*
|
||||
* @return None.
|
||||
*/
|
||||
extern void Batt_Register( battServiceCB_t pfnServiceCB )
|
||||
{
|
||||
battServiceCB = pfnServiceCB;
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_SetParameter
|
||||
*
|
||||
* @brief Set a Battery Service parameter.
|
||||
*
|
||||
* @param param - Profile parameter ID
|
||||
* @param len - length of data to right
|
||||
* @param value - pointer to data to write. This is dependent on
|
||||
* the parameter ID and WILL be cast to the appropriate
|
||||
* data type (example: data type of uint16 will be cast to
|
||||
* uint16 pointer).
|
||||
*
|
||||
* @return bStatus_t
|
||||
*/
|
||||
bStatus_t Batt_SetParameter( uint8 param, uint8 len, void *value )
|
||||
{
|
||||
bStatus_t ret = SUCCESS;
|
||||
|
||||
switch ( param )
|
||||
{
|
||||
case BATT_PARAM_CRITICAL_LEVEL:
|
||||
battCriticalLevel = *((uint8*)value);
|
||||
|
||||
// If below the critical level and critical state not set, notify it
|
||||
if ( battLevel < battCriticalLevel )
|
||||
{
|
||||
battNotifyLevel();
|
||||
}
|
||||
break;
|
||||
|
||||
default:
|
||||
ret = INVALIDPARAMETER;
|
||||
break;
|
||||
}
|
||||
|
||||
return ( ret );
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_GetParameter
|
||||
*
|
||||
* @brief Get a Battery Service parameter.
|
||||
*
|
||||
* @param param - Profile parameter ID
|
||||
* @param value - pointer to data to get. This is dependent on
|
||||
* the parameter ID and WILL be cast to the appropriate
|
||||
* data type (example: data type of uint16 will be cast to
|
||||
* uint16 pointer).
|
||||
*
|
||||
* @return bStatus_t
|
||||
*/
|
||||
bStatus_t Batt_GetParameter( uint8 param, void *value )
|
||||
{
|
||||
bStatus_t ret = SUCCESS;
|
||||
switch ( param )
|
||||
{
|
||||
case BATT_PARAM_LEVEL:
|
||||
*((uint8*)value) = battLevel;
|
||||
break;
|
||||
|
||||
case BATT_PARAM_CRITICAL_LEVEL:
|
||||
*((uint8*)value) = battCriticalLevel;
|
||||
break;
|
||||
|
||||
case BATT_PARAM_SERVICE_HANDLE:
|
||||
*((uint16*)value) = GATT_SERVICE_HANDLE( battAttrTbl );
|
||||
break;
|
||||
|
||||
case BATT_PARAM_BATT_LEVEL_IN_REPORT:
|
||||
{
|
||||
hidRptMap_t *pRpt = (hidRptMap_t *)value;
|
||||
|
||||
pRpt->id = hidReportRefBattLevel[0];
|
||||
pRpt->type = hidReportRefBattLevel[1];
|
||||
pRpt->handle = battAttrTbl[BATT_LEVEL_VALUE_IDX].handle;
|
||||
pRpt->cccdHandle = battAttrTbl[BATT_LEVEL_VALUE_CCCD_IDX].handle;
|
||||
pRpt->mode = HID_PROTOCOL_MODE_REPORT;
|
||||
}
|
||||
break;
|
||||
|
||||
default:
|
||||
ret = INVALIDPARAMETER;
|
||||
break;
|
||||
}
|
||||
|
||||
return ( ret );
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_MeasLevel
|
||||
*
|
||||
* @brief Measure the battery level and update the battery
|
||||
* level value in the service characteristics. If
|
||||
* the battery level-state characteristic is configured
|
||||
* for notification and the battery level has changed
|
||||
* since the last measurement, then a notification
|
||||
* will be sent.
|
||||
*
|
||||
* @return Success
|
||||
*/
|
||||
bStatus_t Batt_MeasLevel( void )
|
||||
{
|
||||
uint8 level;
|
||||
|
||||
level = battMeasure();
|
||||
|
||||
// If level has gone down
|
||||
if (level < battLevel)
|
||||
{
|
||||
// Update level
|
||||
battLevel = level;
|
||||
|
||||
// Send a notification
|
||||
battNotifyLevel();
|
||||
}
|
||||
|
||||
return SUCCESS;
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_Setup
|
||||
*
|
||||
* @brief Set up which ADC source is to be used. Defaults to VDD/3.
|
||||
*
|
||||
* @param adc_ch - ADC Channel, e.g. HAL_ADC_CHN_AIN6
|
||||
* @param minVal - max battery level
|
||||
* @param maxVal - min battery level
|
||||
* @param sCB - HW setup callback
|
||||
* @param tCB - HW tear down callback
|
||||
* @param cCB - percentage calculation callback
|
||||
*
|
||||
* @return none.
|
||||
*/
|
||||
void Batt_Setup( uint8 adc_ch, uint16 minVal, uint16 maxVal,
|
||||
battServiceSetupCB_t sCB, battServiceTeardownCB_t tCB,
|
||||
battServiceCalcCB_t cCB )
|
||||
{
|
||||
battServiceAdcCh = adc_ch;
|
||||
battMinLevel = minVal;
|
||||
battMaxLevel = maxVal;
|
||||
|
||||
battServiceSetupCB = sCB;
|
||||
battServiceTeardownCB = tCB;
|
||||
battServiceCalcCB = cCB;
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn battReadAttrCB
|
||||
*
|
||||
* @brief Read an attribute.
|
||||
*
|
||||
* @param connHandle - connection message was received on
|
||||
* @param pAttr - pointer to attribute
|
||||
* @param pValue - pointer to data to be read
|
||||
* @param pLen - length of data to be read
|
||||
* @param offset - offset of the first octet to be read
|
||||
* @param maxLen - maximum length of data to be read
|
||||
*
|
||||
* @return Success or Failure
|
||||
*/
|
||||
static uint8 battReadAttrCB( uint16 connHandle, gattAttribute_t *pAttr,
|
||||
uint8 *pValue, uint8 *pLen, uint16 offset, uint8 maxLen )
|
||||
{
|
||||
bStatus_t status = SUCCESS;
|
||||
|
||||
// Make sure it's not a blob operation (no attributes in the profile are long)
|
||||
if ( offset > 0 )
|
||||
{
|
||||
return ( ATT_ERR_ATTR_NOT_LONG );
|
||||
}
|
||||
|
||||
uint16 uuid = BUILD_UINT16( pAttr->type.uuid[0], pAttr->type.uuid[1] );
|
||||
|
||||
// Measure battery level if reading level
|
||||
if ( uuid == BATT_LEVEL_UUID )
|
||||
{
|
||||
uint8 level;
|
||||
|
||||
level = battMeasure();
|
||||
|
||||
// If level has gone down
|
||||
if (level < battLevel)
|
||||
{
|
||||
// Update level
|
||||
battLevel = level;
|
||||
}
|
||||
|
||||
*pLen = 1;
|
||||
pValue[0] = battLevel;
|
||||
}
|
||||
else if ( uuid == GATT_REPORT_REF_UUID )
|
||||
{
|
||||
*pLen = HID_REPORT_REF_LEN;
|
||||
osal_memcpy( pValue, pAttr->pValue, HID_REPORT_REF_LEN );
|
||||
}
|
||||
else
|
||||
{
|
||||
status = ATT_ERR_ATTR_NOT_FOUND;
|
||||
}
|
||||
|
||||
return ( status );
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn battWriteAttrCB
|
||||
*
|
||||
* @brief Validate attribute data prior to a write operation
|
||||
*
|
||||
* @param connHandle - connection message was received on
|
||||
* @param pAttr - pointer to attribute
|
||||
* @param pValue - pointer to data to be written
|
||||
* @param len - length of data
|
||||
* @param offset - offset of the first octet to be written
|
||||
*
|
||||
* @return Success or Failure
|
||||
*/
|
||||
static bStatus_t battWriteAttrCB( uint16 connHandle, gattAttribute_t *pAttr,
|
||||
uint8 *pValue, uint8 len, uint16 offset )
|
||||
{
|
||||
bStatus_t status = SUCCESS;
|
||||
|
||||
uint16 uuid = BUILD_UINT16( pAttr->type.uuid[0], pAttr->type.uuid[1]);
|
||||
switch ( uuid )
|
||||
{
|
||||
case GATT_CLIENT_CHAR_CFG_UUID:
|
||||
status = GATTServApp_ProcessCCCWriteReq( connHandle, pAttr, pValue, len,
|
||||
offset, GATT_CLIENT_CFG_NOTIFY );
|
||||
if ( status == SUCCESS )
|
||||
{
|
||||
uint16 charCfg = BUILD_UINT16( pValue[0], pValue[1] );
|
||||
|
||||
if ( battServiceCB )
|
||||
{
|
||||
(*battServiceCB)( (charCfg == GATT_CFG_NO_OPERATION) ?
|
||||
BATT_LEVEL_NOTI_DISABLED :
|
||||
BATT_LEVEL_NOTI_ENABLED);
|
||||
}
|
||||
}
|
||||
break;
|
||||
|
||||
default:
|
||||
status = ATT_ERR_ATTR_NOT_FOUND;
|
||||
break;
|
||||
}
|
||||
|
||||
return ( status );
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn battNotifyCB
|
||||
*
|
||||
* @brief Send a notification of the level state characteristic.
|
||||
*
|
||||
* @param connHandle - linkDB item
|
||||
*
|
||||
* @return None.
|
||||
*/
|
||||
static void battNotifyCB( linkDBItem_t *pLinkItem )
|
||||
{
|
||||
if ( pLinkItem->stateFlags & LINK_CONNECTED )
|
||||
{
|
||||
uint16 value = GATTServApp_ReadCharCfg( pLinkItem->connectionHandle,
|
||||
battLevelClientCharCfg );
|
||||
if ( value & GATT_CLIENT_CFG_NOTIFY )
|
||||
{
|
||||
attHandleValueNoti_t noti;
|
||||
|
||||
noti.handle = battAttrTbl[BATT_LEVEL_VALUE_IDX].handle;
|
||||
noti.len = 1;
|
||||
noti.value[0] = battLevel;
|
||||
|
||||
GATT_Notification( pLinkItem->connectionHandle, ¬i, FALSE );
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn battMeasure
|
||||
*
|
||||
* @brief Measure the battery level with the ADC and return
|
||||
* it as a percentage 0-100%.
|
||||
*
|
||||
* @return Battery level.
|
||||
*/
|
||||
static uint8 battMeasure( void )
|
||||
{
|
||||
uint16 adc;
|
||||
uint8 percent;
|
||||
|
||||
/**
|
||||
* Battery level conversion from ADC to a percentage:
|
||||
*
|
||||
* The maximum ADC value for the battery voltage level is 511 for a
|
||||
* 10-bit conversion. The ADC value is references vs. 1.25v and
|
||||
* this maximum value corresponds to a voltage of 3.75v.
|
||||
*
|
||||
* For a coin cell battery 3.0v = 100%. The minimum operating
|
||||
* voltage of the CC2540 is 2.0v so 2.0v = 0%.
|
||||
*
|
||||
* To convert a voltage to an ADC value use:
|
||||
*
|
||||
* (v/3)/1.25 * 511 = adc
|
||||
*
|
||||
* 3.0v = 409 ADC
|
||||
* 2.0v = 273 ADC
|
||||
*
|
||||
* We need to map ADC values from 409-273 to 100%-0%.
|
||||
*
|
||||
* Normalize the ADC values to zero:
|
||||
*
|
||||
* 409 - 273 = 136
|
||||
*
|
||||
* And convert ADC range to percentage range:
|
||||
*
|
||||
* percent/adc = 100/136 = 25/34
|
||||
*
|
||||
* Resulting in the final equation, with round:
|
||||
*
|
||||
* percent = ((adc - 273) * 25) + 33 / 34
|
||||
*/
|
||||
|
||||
// Call measurement setup callback
|
||||
if (battServiceSetupCB != NULL)
|
||||
{
|
||||
battServiceSetupCB();
|
||||
}
|
||||
|
||||
// Configure ADC and perform a read
|
||||
HalAdcSetReference( HAL_ADC_REF_125V );
|
||||
adc = HalAdcRead( battServiceAdcCh, HAL_ADC_RESOLUTION_10 );
|
||||
|
||||
// Call measurement teardown callback
|
||||
if (battServiceTeardownCB != NULL)
|
||||
{
|
||||
battServiceTeardownCB();
|
||||
}
|
||||
|
||||
if (adc >= battMaxLevel)
|
||||
{
|
||||
percent = 100;
|
||||
}
|
||||
else if (adc <= battMinLevel)
|
||||
{
|
||||
percent = 0;
|
||||
}
|
||||
else
|
||||
{
|
||||
if (battServiceCalcCB != NULL)
|
||||
{
|
||||
percent = battServiceCalcCB(adc);
|
||||
}
|
||||
else
|
||||
{
|
||||
uint16 range = battMaxLevel - battMinLevel + 1;
|
||||
|
||||
// optional if you want to keep it even, otherwise just take floor of divide
|
||||
// range += (range & 1);
|
||||
range >>= 2; // divide by 4
|
||||
|
||||
percent = (uint8) ((((adc - battMinLevel) * 25) + (range - 1)) / range);
|
||||
}
|
||||
}
|
||||
|
||||
return percent;
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn battNotifyLevelState
|
||||
*
|
||||
* @brief Send a notification of the battery level state
|
||||
* characteristic if a connection is established.
|
||||
*
|
||||
* @return None.
|
||||
*/
|
||||
static void battNotifyLevel( void )
|
||||
{
|
||||
// Execute linkDB callback to send notification
|
||||
linkDB_PerformFunc( battNotifyCB );
|
||||
}
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_HandleConnStatusCB
|
||||
*
|
||||
* @brief Battery Service link status change handler function.
|
||||
*
|
||||
* @param connHandle - connection handle
|
||||
* @param changeType - type of change
|
||||
*
|
||||
* @return none
|
||||
*/
|
||||
void Batt_HandleConnStatusCB( uint16 connHandle, uint8 changeType )
|
||||
{
|
||||
// Make sure this is not loopback connection
|
||||
if ( connHandle != LOOPBACK_CONNHANDLE )
|
||||
{
|
||||
// Reset Client Char Config if connection has dropped
|
||||
if ( ( changeType == LINKDB_STATUS_UPDATE_REMOVED ) ||
|
||||
( ( changeType == LINKDB_STATUS_UPDATE_STATEFLAGS ) &&
|
||||
( !linkDB_Up( connHandle ) ) ) )
|
||||
{
|
||||
GATTServApp_InitCharCfg( connHandle, battLevelClientCharCfg );
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/*********************************************************************
|
||||
*********************************************************************/
|
||||
@@ -0,0 +1,206 @@
|
||||
/**************************************************************************************************
|
||||
Filename: battservice.h
|
||||
Revised: $Date $
|
||||
Revision: $Revision $
|
||||
|
||||
Description: This file contains the Battery service definitions and
|
||||
prototypes.
|
||||
|
||||
Copyright 2011-2013 Texas Instruments Incorporated. All rights reserved.
|
||||
|
||||
IMPORTANT: Your use of this Software is limited to those specific rights
|
||||
granted under the terms of a software license agreement between the user
|
||||
who downloaded the software, his/her employer (which must be your employer)
|
||||
and Texas Instruments Incorporated (the "License"). You may not use this
|
||||
Software unless you agree to abide by the terms of the License. The License
|
||||
limits your use, and you acknowledge, that the Software may not be modified,
|
||||
copied or distributed unless embedded on a Texas Instruments microcontroller
|
||||
or used solely and exclusively in conjunction with a Texas Instruments radio
|
||||
frequency transceiver, which is integrated into your product. Other than for
|
||||
the foregoing purpose, you may not use, reproduce, copy, prepare derivative
|
||||
works of, modify, distribute, perform, display or sell this Software and/or
|
||||
its documentation for any purpose.
|
||||
|
||||
YOU FURTHER ACKNOWLEDGE AND AGREE THAT THE SOFTWARE AND DOCUMENTATION ARE
|
||||
PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED,
|
||||
INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, TITLE,
|
||||
NON-INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
|
||||
TEXAS INSTRUMENTS OR ITS LICENSORS BE LIABLE OR OBLIGATED UNDER CONTRACT,
|
||||
NEGLIGENCE, STRICT LIABILITY, CONTRIBUTION, BREACH OF WARRANTY, OR OTHER
|
||||
LEGAL EQUITABLE THEORY ANY DIRECT OR INDIRECT DAMAGES OR EXPENSES
|
||||
INCLUDING BUT NOT LIMITED TO ANY INCIDENTAL, SPECIAL, INDIRECT, PUNITIVE
|
||||
OR CONSEQUENTIAL DAMAGES, LOST PROFITS OR LOST DATA, COST OF PROCUREMENT
|
||||
OF SUBSTITUTE GOODS, TECHNOLOGY, SERVICES, OR ANY CLAIMS BY THIRD PARTIES
|
||||
(INCLUDING BUT NOT LIMITED TO ANY DEFENSE THEREOF), OR OTHER SIMILAR COSTS.
|
||||
|
||||
Should you have any questions regarding your right to use this Software,
|
||||
contact Texas Instruments Incorporated at www.TI.com.
|
||||
**************************************************************************************************/
|
||||
|
||||
#ifndef BATTSERVICE_H
|
||||
#define BATTSERVICE_H
|
||||
|
||||
#ifdef __cplusplus
|
||||
extern "C"
|
||||
{
|
||||
#endif
|
||||
|
||||
/*********************************************************************
|
||||
* INCLUDES
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* CONSTANTS
|
||||
*/
|
||||
|
||||
|
||||
// Battery Service UUIDs
|
||||
#define BATT_SERVICE_UUID 0x180F // Battery Service
|
||||
#define BATT_LEVEL_UUID 0x2A19 // Battery Level
|
||||
|
||||
// Battery Service Get/Set Parameters
|
||||
#define BATT_PARAM_LEVEL 0
|
||||
#define BATT_PARAM_CRITICAL_LEVEL 1
|
||||
#define BATT_PARAM_SERVICE_HANDLE 2
|
||||
#define BATT_PARAM_BATT_LEVEL_IN_REPORT 3
|
||||
|
||||
// Callback events
|
||||
#define BATT_LEVEL_NOTI_ENABLED 1
|
||||
#define BATT_LEVEL_NOTI_DISABLED 2
|
||||
|
||||
// HID Report IDs for the service
|
||||
#define HID_RPT_ID_BATT_LEVEL_IN 4 // Battery Level input report ID
|
||||
|
||||
/*********************************************************************
|
||||
* TYPEDEFS
|
||||
*/
|
||||
|
||||
// Battery Service callback function
|
||||
typedef void (*battServiceCB_t)(uint8 event);
|
||||
|
||||
// Battery measure HW setup function
|
||||
typedef void (*battServiceSetupCB_t)(void);
|
||||
|
||||
// Battery measure percentage calculation function
|
||||
typedef uint8 (*battServiceCalcCB_t)(uint16 adcVal);
|
||||
|
||||
// Battery measure HW teardown function
|
||||
typedef void (*battServiceTeardownCB_t)(void);
|
||||
|
||||
/*********************************************************************
|
||||
* MACROS
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* Profile Callbacks
|
||||
*/
|
||||
|
||||
|
||||
/*********************************************************************
|
||||
* API FUNCTIONS
|
||||
*/
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_AddService
|
||||
*
|
||||
* @brief Initializes the Battery service by registering
|
||||
* GATT attributes with the GATT server.
|
||||
*
|
||||
* @return Success or Failure
|
||||
*/
|
||||
extern bStatus_t Batt_AddService( void );
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_Register
|
||||
*
|
||||
* @brief Register a callback function with the Battery Service.
|
||||
*
|
||||
* @param pfnServiceCB - Callback function.
|
||||
*
|
||||
* @return None.
|
||||
*/
|
||||
extern void Batt_Register( battServiceCB_t pfnServiceCB );
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_SetParameter
|
||||
*
|
||||
* @brief Set a Battery Service parameter.
|
||||
*
|
||||
* @param param - Profile parameter ID
|
||||
* @param len - length of data to right
|
||||
* @param value - pointer to data to write. This is dependent on
|
||||
* the parameter ID and WILL be cast to the appropriate
|
||||
* data type (example: data type of uint16 will be cast to
|
||||
* uint16 pointer).
|
||||
*
|
||||
* @return bStatus_t
|
||||
*/
|
||||
extern bStatus_t Batt_SetParameter( uint8 param, uint8 len, void *value );
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_GetParameter
|
||||
*
|
||||
* @brief Get a Battery parameter.
|
||||
*
|
||||
* @param param - Profile parameter ID
|
||||
* @param value - pointer to data to get. This is dependent on
|
||||
* the parameter ID and WILL be cast to the appropriate
|
||||
* data type (example: data type of uint16 will be cast to
|
||||
* uint16 pointer).
|
||||
*
|
||||
* @return bStatus_t
|
||||
*/
|
||||
extern bStatus_t Batt_GetParameter( uint8 param, void *value );
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_MeasLevel
|
||||
*
|
||||
* @brief Measure the battery level and update the battery
|
||||
* level value in the service characteristics. If
|
||||
* the battery level-state characteristic is configured
|
||||
* for notification and the battery level has changed
|
||||
* since the last measurement, then a notification
|
||||
* will be sent.
|
||||
*
|
||||
* @return Success or Failure
|
||||
*/
|
||||
extern bStatus_t Batt_MeasLevel( void );
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_Setup
|
||||
*
|
||||
* @brief Set up which ADC source is to be used. Defaults to VDD/3.
|
||||
*
|
||||
* @param adc_ch - ADC Channel, e.g. HAL_ADC_CHN_AIN6
|
||||
* @param minVal - max battery level
|
||||
* @param maxVal - min battery level
|
||||
* @param sCB - HW setup callback
|
||||
* @param tCB - HW tear down callback
|
||||
* @param cCB - percentage calculation callback
|
||||
*
|
||||
* @return none.
|
||||
*/
|
||||
extern void Batt_Setup( uint8 adc_ch, uint16 minVal, uint16 maxVal,
|
||||
battServiceSetupCB_t sCB, battServiceTeardownCB_t tCB,
|
||||
battServiceCalcCB_t cCB );
|
||||
|
||||
/*********************************************************************
|
||||
* @fn Batt_HandleConnStatusCB
|
||||
*
|
||||
* @brief Battery Service link status change handler function.
|
||||
*
|
||||
* @param connHandle - connection handle
|
||||
* @param changeType - type of change
|
||||
*
|
||||
* @return none
|
||||
*/
|
||||
void Batt_HandleConnStatusCB( uint16 connHandle, uint8 changeType );
|
||||
|
||||
/*********************************************************************
|
||||
*********************************************************************/
|
||||
|
||||
#ifdef __cplusplus
|
||||
}
|
||||
#endif
|
||||
|
||||
#endif /* BATTSERVICE_H */
|
||||
Reference in New Issue